Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
1.
Lancet Reg Health Southeast Asia ; 10: 100139, 2023 Mar.
Article in English | MEDLINE | ID: covidwho-2181313

ABSTRACT

Background: NVX-CoV2373, a Covid-19 vaccine was developed in the USA with ∼90% efficacy. The same vaccine is manufactured in India after technology transfer (called as SII-NVX-CoV2373), was evaluated in this phase 2/3 immuno-bridging study. Methods: This was an observer-blind, randomised, phase 2/3 study in 1600 adults. In phase 2, 200 participants were randomized 3:1 to SII-NVX-CoV2373 or placebo. In phase 3, 1400 participants were randomized 3:1 to SII-NVX-CoV2373 or NVX-CoV2373 (940 safety cohort and 460 immunogenicity cohort). Two doses of study products (SII-NVX-CoV2373, NVX-CoV2373 or placebo) were given 3 weeks apart. Primary objectives were to demonstrate non-inferiority of SII-NVX-CoV2373 to NVX-CoV2373 in terms of geometric mean ELISA units (GMEU) ratio of anti-S IgG antibodies 14 days after the second dose (day 36) and to determine the incidence of causally related serious adverse events (SAEs) through 180 days after the first dose. Anti-S IgG response was assessed using an Enzyme-Linked Immunosorbent Assay (ELISA) and neutralizing antibodies (nAb) were assessed by a microneutralization assay using wild type SARS CoV-2 in participants from the immunogenicity cohort at baseline, day 22, day 36 and day 180. Cell mediated immune (CMI) response was assessed in a subset of 28 participants from immunogenicity cohort by ELISpot assay at baseline, day 36 and day 180. The total follow-up was for 6 months. Trial registration: CTRI/2021/02/031554. Findings: Total 1596 participants (200 in Phase 2 and 1396 in Phase 3) received the first dose. SII-NVX-CoV2373 was found non-inferior to NVX-CoV2373 (anti-S IgG antibodies GMEU ratio 0.91; 95% CI: 0.79, 1.06). At day 36, there was more than 58-fold rise in anti-S IgG and nAb titers compared to baseline in both the groups. On day 180 visit, these antibody titers declined to levels slightly lower than those after the first dose (13-22 fold-rise above baseline). Incidence of unsolicited and solicited AEs was similar between the SII-NVX-CoV2373 and NVX-CoV2373 groups. No adverse event of special interest (AESI) was reported. No causally related SAE was reported. Interpretation: SII-NVX-CoV2373 induced a non-inferior immune response compared to NVX-CoV2373 and has acceptable safety profile. Funding: SIIPL, Indian Council of Medical Research, Novavax.

2.
J Med Microbiol ; 69(9): 1169-1178, 2020 Sep.
Article in English | MEDLINE | ID: covidwho-696076

ABSTRACT

Introduction. The SARS-CoV-2 pandemic of 2020 has resulted in unparalleled requirements for RNA extraction kits and enzymes required for virus detection, leading to global shortages. This has necessitated the exploration of alternative diagnostic options to alleviate supply chain issues.Aim. To establish and validate a reverse transcription loop-mediated isothermal amplification (RT- LAMP) assay for the detection of SARS-CoV-2 from nasopharyngeal swabs.Methodology. We used a commercial RT-LAMP mastermix from OptiGene in combination with a primer set designed to detect the CDC N1 region of the SARS-CoV-2 nucleocapsid (N) gene. A single-tube, single-step fluorescence assay was implemented whereby 1 µl of universal transport medium (UTM) directly from a nasopharyngeal swab could be used as template, bypassing the requirement for RNA purification. Amplification and detection could be conducted in any thermocycler capable of holding 65 °C for 30 min and measure fluorescence in the FAM channel at 1 min intervals.Results. Assay evaluation by assessment of 157 clinical specimens previously screened by E-gene RT-qPCR revealed assay sensitivity and specificity of 87 and 100%, respectively. Results were fast, with an average time-to-positive (Tp) for 93 clinical samples of 14 min (sd±7 min). Using dilutions of SARS-CoV-2 virus spiked into UTM, we also evaluated assay performance against FDA guidelines for implementation of emergency-use diagnostics and established a limit-of-detection of 54 Tissue Culture Infectious Dose 50 per ml (TCID50 ml-1), with satisfactory assay sensitivity and specificity. A comparison of 20 clinical specimens between four laboratories showed excellent interlaboratory concordance; performing equally well on three different, commonly used thermocyclers, pointing to the robustness of the assay.Conclusion. With a simplified workflow, The N1 gene Single Tube Optigene LAMP assay (N1-STOP-LAMP) is a powerful, scalable option for specific and rapid detection of SARS-CoV-2 and an additional resource in the diagnostic armamentarium against COVID-19.


Subject(s)
Coronavirus Infections/diagnosis , Nucleic Acid Amplification Techniques/methods , Pneumonia, Viral/diagnosis , Betacoronavirus , COVID-19 , COVID-19 Testing , COVID-19 Vaccines , Clinical Laboratory Techniques , Humans , Molecular Diagnostic Techniques/methods , Nasopharynx/virology , Pandemics , RNA, Viral , Real-Time Polymerase Chain Reaction , Reverse Transcriptase Polymerase Chain Reaction , Reverse Transcription , SARS-CoV-2 , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL